Combi Boilers

 

Chimney (Open Flue) Type Feature Hermetik (Balanced Flue) Type


FEATURES

Elegant Design
High efficiency and low consumption with the help of full time modulation
Intelligent ignition system as 3 times
Warning system with ring and display
Suitable for floor heaing system
Anti freeze function
Safety system for chimmey blockage
Thermostatic safety system for over heating
Anti blockage system for pump
Special heat exchanger designed for comfortable usage
Flow control of room thermostat and timer connection
Eletronic card suitable for low and high voltages
Special EMC filter for stability of Electronic card
Thank to special service menu which helps arrenging radiator capacity ignition time and thermostat aiting duration without opening cover
Special display shows arranged and measured temperature
Safety system (max. 3 bar) for central heating system
Safety system (min. 0.8 bar) for low water pressure
High quality 3 stage special pump
Gas valve manufactured with high tecnology
Thanks to ideal dimentions matching every small areas

Models

BK 20 EST CHIMNEY TYPE COMBO ELC.IGNITION SILENT TOUCH 23,2 KW 20.000 Kcal
HK 20 EST HERMETIC TYPE COMBO ELC.IGNITION SILENT TOUCH 23,2 KW 20.000 Kcal
BK 24 EST CHIMNEY TYPE COMBO ELC.IGNITION SILENT TOUCH 28 KW 24.000 Kcal
HK 24 EST HERMETIC TYPE COMBO ELC.IGNITION SILENT TOUCH 28 KW 24.000 Kcal
 

 
 
Chimney Type
1- Control Panel
2- Heating Water Flipping Tap
3- Sanitary Water Sensor
4- Central Heating Sensor
5- Central Heating Water Pressure Switch
6- Gas Valve
7- Flame Sensor
8- Explasion Tank
9- Chimney
10- Air Purger
11- Heat Exchanger
12- Burner
13- Limit Thermostat
14- Circulation Pump
15- Sanitary Water Pressure Switch
16- Safety Valve

Hermetic Type
1- Control Panel
2- Heating Water Flipping Tap
3- Sanitary Water Sensor
4- Central Heating Sensor
5- Central Heating Water Pressure Switch
6- Gas Valve
7- Flame Sensor
8- Explasion Tank
9- Chimney
10- Air Purger
11- Heat Exchanger
12- Burner
13- Limit Thermostat
14- Circulation Pump
15- Sanitary Water Pressure Switch
16- Safety Valve
17- Exhaust
18- Air Pressure Switch

Technical Specifications
 
Models
Unit
BK 20E
HK 20E
Max. Heating Capacity
kW
kcal/h
26.3
22.600
26.3
22.600
Min. Heating Capacity
kW
kcal/h
8.2
7.100
8.2
7.100
Max. Heating Power
kW
kcal/h
23.3
20.000
23.3
20.000
Min. Heating Power
kW
kcal/h
7.0
6.000
7.0
6.000
Max. Central Heating Water Pressure
Bar
3
3
Max. Sanitary Water Pressure
Bar
6
6
Min. Sanitary Water Pressure
Bar
0.3
0.3
Sanitary Water Flow
lt/dk
13.3
13.3
Max. Central Heating Water Temperature
°C
85
85
Sanitary Water Temperature
°C
35-65
35-65
Max. Natural Gas Comsumption
Nm3/h
2.4
2.4
Max. LPG Comsumption
Kg/h
1.78
1.78
Gas Inlet Pressure (LPG)
mbar
30
30
(NG)
mbar
20
20
Expation Tank Capacity
lt
8
8
Chimney Diameter
mm
115
100
Fan Connection
mm
-
60
Heating System Connection (Outlet/Inlet)
inch
3/4
3/4
Sanitary Water (Outlet/Inlet)
inch
1/2
1/2
Gas Connection
inch
1/2
1/2
Electric Connection
V/P/Hz
230/1/50
230/1/50
Max. Electric Consumption
W
110
110
Net Dimensions
mm
370 x 420 x 795
370 x 420 x 795
Net Weight
Kg.
36
36
 

About Us | Air Curtains | Natural Gas Stoves | Infrared Stoves | Combi Boilers | Quartz Heaters | Free Standing Electric Ovens | Free Standing Gas Ovens
Built in Ovens | Table Top Cookers | Built in Cookers | Toaster Ovens | Cookerhoods | Contact
© 2006 -AsRoyal Heating Cooling & Cooking Systems - All Right Reserved